[vc_row][vc_column][vc_column_text]General Definition of Command Frame:
Addr Range: 0x8001~0xFFFF, LSB first, then MSB, default = 0xFF 0xFF[/vc_column_text][vc_tour][vc_tab title=”Identify 18000-6B ” tab_id=”1393308972-1-80″][vc_column_text]Direction of data flow: host -> RFID reader
Example:7C FF FF 01 07 7E
Returned message: success or Failure
Direction of data flow: RFID reader -> Host
Success:
Example:CC FF FF 02 07 01 00 002C
Failure :
Example:CC FF FF 02 07 00 xx[/vc_column_text][/vc_tab][vc_tab title=” Read 18000-6B RFID Tag ” tab_id=”1393308972-2-15″][vc_column_text]Direction of data flow: Host -> RFID reader
Example:7C FF FF 02 07 12 02 69
Returned message: success or Failure
Direction of data flow: RFID reader-> Host
Success:
Example:CC FF FF 02 07 01 00 002C
Failure :
Example:CC FF FF 02 07 00 xx[/vc_column_text][/vc_tab][vc_tab title=”Write 18000-6B RFID Tag” tab_id=”1393366742658-2-9″][vc_column_text]Direction of data flow: Host -> RFID reader
Note: The Tag Address of 18000-6B should start from 18.
Example:7C FF FF 03 07 12 02 01 02 65
Returned message: success or Failure
Direction of data flow: RFID reader -> Host
Success:
Example:CC FF FF 03 07 012B
Example:CC FF FF 03 07 00 xx[/vc_column_text][/vc_tab][vc_tab title=”Identify EPC Tag ” tab_id=”1393366744009-3-4″][vc_column_text]Direction of data flow: Host -> RFID reader
Example:7C FF FF 01 08 7D
Returned message: success or Failure
Direction of data flow: RFID reader -> Host
Success:
Example:CC FF FF 01 08 01 25 00 11 00 AB EE AF C1 EC 88 85 1ADA
Failure:
Example:CC FF FF 01 08 00 xx[/vc_column_text][/vc_tab][vc_tab title=”Read EPC Tag” tab_id=”1393366745069-4-9″][vc_column_text]Direction of data flow: Host -> RFID reader
Example:7C FF FF 02 08 01 02 01 78
Returned message: success or Failure
Direction of data flow: RFID reader -> Host
Success:
Example:CC FF FF 02 0801 25 0006
Failure:
Example:CC FF FF 02 0800 xx[/vc_column_text][/vc_tab][vc_tab title=”Write EPC Tag” tab_id=”1393367337322-5-2″][vc_column_text]Direction of data flow: Host -> RFID reader
Note: write EPC block’s tag address starts from 2.
Example:7C FF FF 03 08 01 02 01 01 02 74
Returned message: success or Failure
Direction of data flow: Host -> RFID reader
Success:
Example:CC FF FF 03 08 012A
Failure:
Example:CC FF FF 03 08 00xx[/vc_column_text][/vc_tab][vc_tab title=”Configure Parameters” tab_id=”1393367338570-6-10″][vc_column_text]Direction of data flow: Host -> RFID reader
Parameter description:Example:7C FF FF 81 30 12 01 1A 01 06 0B 10 15 1A 02 05 00 03 00 1E 0A
0F 01 10 01 01 03
Returned message: success or Failure
Direction of data flow: RFID reader -> Host
Success:Example:CC FF FF 81 30 0184
Failure:Example:CC FF FF 81 30 00xx[/vc_column_text][/vc_tab][vc_tab title=”Reference Equation ” tab_id=”1393367378591-7-2″][vc_column_text]unsigned char CheckSum(unsigned char *uBuff, unsigned char uBuffLen)
{
unsigned char i,uSum=0;
for(i=0;i<uBuffLen;i++)
{
uSum = uSum + uBuff[i];
}
uSum = (~uSum) + 1;
return uSum;
}[/vc_column_text][/vc_tab][/vc_tour][/vc_column][/vc_row]